Proposed mechanisms of action of anti-drug antibody (ADA) against emicizumab. Non-neutralizing ADAs may promote immune complex formation and clearance of emicizumab. Neutralizing ADAs interfere with emicizumab’s ability to bind FIXa and FX, preventing FXa production.
Müller J, Büchsel M, Oleshko O, Pezeshkpoor B, Sachs U, Scholz U, Tiede A. Laboratory Monitoring in Patients Receiving Emicizumab. Hamostaseologie. 2025 Oct 9. doi: 10.1055/a-2687-0107. Epub ahead of print. PMID: 41067253.
Emicizumab
Anti-emicizumab antibody detection and emicizumab plasma concentration
Emicizumab is a bispecific monoclonal antibody used to treat people with haemophilia A, both with and without inhibitors.
Questions addressed by this sub-study
- Could anti-emicizumab antibodies affect the management of people with inhibitors receiving emicizumab prophylaxis?
- Could the development of anti-emicizumab antibodies affect immune tolerance induction (ITI) outcomes?
Participants in MOTIVATE Groups 2 and 3 receive emicizumab prophylaxis. Monitoring emicizumab concentrations and the development of neutralising antibodies may help assess treatment efficacy and patient outcomes. In Group 2, it may also help assess the impact on ITI efficacy.
Objectives
- To measure emicizumab plasma concentrations over time.
- To detect and quantify anti-emicizumab antibodies.
- To assess the impact of these antibodies on treatment efficacy in participants in Groups 2 and 3.
Clinical studies and real-world experience have shown that anti-drug antibodies to emicizumab can develop and may affect treatment, resulting in lower emicizumab plasma concentrations (Pezeshkpoor B et al., 2022, 2024; Schmitt et al., 2021; Kaneda et al., 2021).
Participants receiving ITI with FVIII and emicizumab (Group 2), or emicizumab prophylaxis (Group 3), are eligible for this additional central laboratory immunoassay, particularly if a change in treatment response or additional complications are observed. The same principle will apply to other non-factor therapies (i.e. F8-mimetics other than emicizumab), if applicable.
This Luminex immunoassay enables the simultaneous detection and profiling of antibodies against emicizumab (Pezeshkpoor B et al., 2022).
Sub-study lead investigators
Johannes Oldenburg
Director, Institute for Experimental Haematology and Transfusion Medicine (IHT).
Bonn, Germany
Behnaz Pezeshkpoor
Institute for Experimental Haematology and Transfusion Medicine (IHT),
Bonn, Germany
MOTIVATE will assess the impact of anti-emicizumab antibodies on emicizumab plasma concentrations and treatment outcomes in patients receiving emicizumab prophylaxis.
What is needed for this analysis?
A 1.8 mL blood sample collected at baseline and follow-up, as required.